
SC UPC To SC UPC SM Simplex Optical Fiber Patch Cord
Key Features
- High-quality materials and construction
- Industry standard compliance
- Rigorous quality testing
High-Density SC/UPC Simplex Patch Cord for Enterprise Networks
Telhua's SC UPC to SC UPC SM Simplex Optical Fiber Patch Cord delivers reliable, high-performance connectivity for data centers, enterprise networks, and telecommunications infrastructure. Engineered for maximum port density and installation efficiency, this patch cord eliminates signal loss and downtime in critical B2B environments where space optimization and network reliability are paramount.
Addressing Key B2B Installation Challenges
Network engineers and data center managers face constant pressure to maximize rack space while maintaining flawless connectivity. Our SC/UPC simplex patch cords are specifically designed to overcome these challenges:
- Space Optimization: The compact SC connector design enables higher port density compared to bulkier alternatives, allowing more connections in limited rack space
- Installation Efficiency: Precise connector geometry ensures quick, secure mating without excessive force or alignment issues that delay deployment
- Reliability Assurance: Factory-terminated and 100% tested to eliminate field termination errors that cause network downtime and service interruptions
- Performance Consistency: Ultra-low insertion loss maintains signal integrity across your entire network infrastructure
Technical Specifications
| Specification | Value |
|---|---|
| Connector Type | SC/UPC to SC/UPC |
| Fiber Type | Single Mode (SM) |
| Insertion Loss | ≤ 0.2 dB |
| Return Loss | ≥ 55 dB |
| Cable Diameter | 2.0 mm / 3.0 mm |
| Operating Temperature | -40°C to +85°C |
| Standard Lengths | 1m, 2m, 3m, 5m, 10m, 15m, 20m |
| Compliance Standards | IEC 61754-4, TIA/EIA-604-4, RoHS |
Telhua Engineer's Tip: Optimizing SC/UPC Patch Cord Performance
For maximum reliability in high-density applications, always verify connector end-face cleanliness before installation. Microscopic contaminants invisible to the naked eye can cause intermittent signal loss that's difficult to diagnose. Use a fiber inspection scope with at least 200x magnification to ensure end-faces meet IEC 61300-3-35 cleanliness standards. This simple 30-second check prevents 90% of field performance issues and extends connector lifespan by preventing physical damage during repeated cleaning cycles.
Standards Compliance & Quality Assurance
Every Telhua SC/UPC simplex patch cord undergoes rigorous testing to ensure compliance with international standards. Our manufacturing process adheres to IEC 61754-4 for connector interface dimensions, TIA/EIA-604-4 for performance requirements, and RoHS directives for environmental safety. Each unit is individually tested for insertion loss, return loss, and mechanical durability before shipment, providing the consistent quality that enterprise networks require.




