How to detect whether the optical fiber construction meets the standard? Read this article enough

Preface

When doing intelligent weak current projects, when it comes to the long-distance data transmission of the camera, the use of optical fiber will be given priority. Optical fiber transmission has the advantages of large bandwidth, long transmission distance, and strong anti-interference. But after the fiber fusion splicing is over, is there a way to quickly know that the fiber fusion splicing has been connected and has reached the technical standard? Today we will talk about the methods to detect whether the optical fiber construction meets the standard.

Text

After the fiber fusion splicing is over, there are currently two simple fiber testing methods that are using a red light pen to test the continuity and using an optical power meter to test the optical power of the fiber. After the completion of the entire integrated wiring and wiring project, the fiber channel and link will be tested, and the entire project will be accepted.

1. Red light pen test

After the fiber fusion splicing is completed, the fiber optic continuity test is performed. The most used tool is the red light pen, which functions similar to the network cable tester in the network cable test. The test method is very simple. The optical fiber pigtail connector is connected to the red light pen, and the red light pen device emits visible light. In addition, check whether there is red light on the optical fiber to determine whether there is a disconnection in the middle of the optical fiber.

red light pen

red light pen

Now the latest fiber optic red pens support pigtail FC interface, pigtail ST interface, and pigtail SC interface, which are enough to meet our needs. It is very convenient to verify the fiber connection by lighting. The price of optical fiber red light pen is not very cheap, and the price of ordinary optical fiber red light pen on the market is only tens of dollars, which is very cost-effective.

red light pen 2

red light pen 2

In the red light pen test, one end is connected to the pigtail, and the other end can see red visible light.

red light pen test

red light pen test

2. Optical power meter test

The main function of the optical power meter is to test the relative loss of optical fiber optical power. Generally, after the red light pen lighting test is normal, but the optical fiber network still has problems, this tool needs to be used to test the optical power value.

Optical power meter

Optical power meter

The receiving sensitivity value is specified in the optical fiber transceiver specifications. Use an optical power meter to test the optical power of the optical fiber. As long as it is less than this value, it means that the optical fiber is folded or the optical fiber is of poor quality, and the optical fiber needs to be replaced.

Optical fiber transceiver specifications

Optical fiber transceiver specifications

3. Optical fiber engineering test acceptance

Refer to the General Cabling System Engineering Acceptance Specification GB/T 50312-2016, the optical fiber link test needs to clean all the optical fiber connection components of the general cabling system project, and the test receiver should be calibrated to zero. For details, please refer to Appendix C of this standard for fiber channel and link testing.

General wiring acceptance specification

General wiring acceptance specification

The performance indicators and optical fiber channel indicators of the optical fiber used in the integrated wiring project should meet the design requirements and should meet the following specifications.

3.1 The maximum attenuation value per kilometer of different types of optical cables at the nominal wavelength should meet the specifications in the following table.

Optical fiber attenuation limit

Optical fiber attenuation limit

3.2 The maximum optical attenuation measured by the optical cable wiring channel in the specified transmission window should not be greater than the value in the table below, and the indicator should include the attenuation of the optical fiber connection point and the connecting device.

Optical cable channel attenuation range

Optical cable channel attenuation range

4. Conclusion

The implementation of optical fiber is a part of the integrated wiring system. Generally, it is widely used in the vertical trunk line subsystem and the building group subsystem, and needs to follow the engineering design specifications of the integrated wiring system. After deployment and implementation, you can use a red light pen or optical power meter to test the continuity and optical power of the optical fiber link